<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>3035</ErrorNumber>
<ErrorFamily>Workstation Communications</ErrorFamily>
<ErrorMessage>
WSCOMM: Images pending on bay, can't load
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
An attempt has been made to load a bay which a queued image needs to pick a plate from.  Loading of the
bay is prevented so that the plate size is not changed and the incorrect plate picked by the queued image.
There have been known firmware bugs which cause this error even when no images are due to be picked
from a bay.  The recorder must be reset, or the NVS state parameter reset to zero: "set state bay &lt;bay&gt;
pend 0".
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
If there are images waiting to pick from the bay, the bay loading procedure outlined in the operator's
manual should be followed.  Otherwise, the recorder must be rebooted.  Also, please inform Creo service
of this message.
</text></DescriptionText>
</OperatorAction>
<Cause>
An attempt has been made to load a bay which has an image queued up for it.
</Cause>
<Cause>
A firmware bug is preventing the bay load.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/bay_state_pend.xml</LinkAddress><LinkTitle>NVS: bay pend</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:20 2008 PST
</Updated>
<Links>
</Links>
</Error>